Spanish Banner: Intercambio de Enlaces
Spanish Banner: Intercambio de Enlaces.

CONTADOR DE PECES

Retornar a Falke
THE SINGLE CHANEL COUNTER
One man can easily handle and operate the Single Channel Counter
Main Features:
*A 12 V battery-powered Display Unit with a single outlet for a scanner
*A charger for battery
*A Bioscanner Scanner Unit
*A chanel; for small fish (V-channel 1), for big fish(V-channel 3)
Technical Specifications
Power Supply: 12V DC internal rechargeable battery.
Display Unit: Weatherproof (IP 66)
Scanner Unit: Weaterproof (IP 67)
Performance:
FISH SIZE CAPACITY
V-channel 1 3 - 750 g(0.1 - 26 oz) 25,000 10g (0.3 oz) fish/hour
V-channel 3 500g - 6 kg(1 - 13 lbs) 5,000 2 kg (4 lbs) fish/hour
Accuracy: 98-100%
BIOSCANNER FISH COUNTER
BASIC UNITS
Gather and displays data from um four scanners.
The control unit also supplies power to the scanners. To distinguish between and to count two fish coming down the channel simultaneously, the microprocessor based counter uses an advanced from the scanning.
Mains voltage: 220 V or 110 V, 50/60 Hz standard.
12 V DC optional, 2 m (6 ft) lead
Degree of protection of enclosure; IP 65, according to standards IEC 529 and DIN 40 050.
Four data input lines.
One data input/output line for extra accessories.
Dimensions: 35cm x 28 cm x 17 cm (14" x 11" x 7")
Weight: 7 kg (15.4 lbs)
Control Units
The Scanner Unit'sees' the fish as they pass through the V-Channel, counts them and relays data to the control unit via the connector lead.
Degree of protection of enclosure;
IP 67, according to standard IEC 529 and DIN 4o 050.
Connector lead 15 m (45 ft) standard length. multiples of this trough end-to-end connection.
Dimensions: 25 cm x 10 cm x 35 cm (10" x 4" x 14")
Weight: 3 kg (6.6 lbs)
Scanner Unit
Regulate the flow of fish and water and separate the fish, making it possible to count them.
There are different V-Channels available for different fish sizes and applications.
V-Channels

THE BIOSCANNER COUNTING TUB
FOR SMALL FISH
Vaki's Counting Tub is designed for counting live
Fish in the size range 3 g - 100 g (0.1 oz - 3.5 oz).
Technical Specifications
Fish size : 3 g - 100 g (0.1 oz to 3.5 oz)
Dimensions: 150 cm x 70 cm x 90 cm ( 59" x 28" x 35"
Weight: 25 kg (50 lbs)
Capacity : 50,000 10 g fish per hour.
Accuracy: 98 - 100%
The Counting Tub Consists of:
*an acryl channel on a stainless steel frame
*one Bioscanner Control Unit.
*two Scanner Units
THE BIOSCANNER V - CHANNEL 1
FOR SMALL AND MEDIUM SIZED FISH
For counting fish in the size range
3 g - 700 g (0.1 oz - 1.5 lbs).
V-channel 1 is easy to fix on the end of a pipe leading, e.g. from a grading machine
Technical Specifications
Fish size: 3 g - 700 g (0.1 oz - 1.5 lbs)
Dimensions: 150 cm x 40 cm x 32 cm (59" x 15" x 12")
Weight: 7 kg (15.4 lbs)
Capacity: 25,000 10 g (0.3 oz) fish per hour.
THE BIOSCANNER V-CHANNEL 3
FOR BIG FISH
For counting fish in the size range
500 g - 6 kg(1 lb - 13 lbs)
V-channel 3 is easy to fix on the end of a pipe leading, e.g., from a grading machine.
Technical Specifications
Fish size : 500 g - 6 kg (1 lb - 13 lbs)
Dimensions: 100 cm x 32 cm x 28 cm (39" x 12" x 11")
Weight: 5 kg (11 lbs)
capacity: 2,500 4 kg fish per hour
Audio Alarm
To alert the fish farmer when the desired number of fish have passed through each V-channel.
The alarm is connected and programmed through the EXT output on the control unit.
FALKE LTDA. FAX (56-2) 2270021 - FONO(56-2) 2277707 SANTIAG0 / CHILE
Retornar a Falke