Leakage Current Prediction
Correlate Is0 to F by fitting to long-channel (L = 10 mm) Ioff-F data
Is0 = 1/(0.07 + 0.3526F) [pA/mm]
Wafer #15 used for parameter extraction; wafers #17, #18, #19 10-mm Ioff data used for correlation; others by prediction.