Wall  Thickness  Spot  Checks
 

To  verify  that  the  wall  thickness  of  pipes  have  not  reduced  due  to  either  wear  and  tear  or  extended  storage , it  is  often  advisable  to  carry  out  Wall  Thickness  Spot  Checks  on  casing  before  using.
 

These  spot  checks  are  done  with  a  Ultrasonic  Gauge  which  is  calibrated  with  specified  reference  standards. The  spot  checks  are  carried  out  in  a  pre-determined  pattern  and  the  trend  is  recorded.

If  the  wall  thickness  values  are  observed  to  be  critically  low  or  below  the  nominal  values , a  more  through  Full  Body  Ultrasonic  Inspection   would  be  recommended  to  verify  the  integrity  of  the  material.

API  specifies  a  minimum  criterion  for  the  wall  thickness  and  to  use  material  below  these  ratings  would  most  likely  lead  to  blow-outs  and  expensive  operational   down-time.

Tuboscope  Indonesia  has  a  recommended  practise  of  inspection  of  at  least  12  spots  along  the  casing. These  are  done  in  four  quadrant  positions  and  generally  done  at  the  ends  and  in  the  center.

The  number  of  check  points  can  be  increased  if  there  is  any  doubt  about  the  integrity  of  the  tubulars  or  visual  inspections  indicate  massive  pittings   and / or  corrosion. We  have  inspected  under  special  considerations  a  maximum  of  12 quadrant  positions  at  a  spacing  of  12  inches  apart.
 
Please  contact   Tuboscope , Indonesia   for  further  information.
 

 
                                                                                                                                      
 
 

 Web Site created and maintained by  Jayesh  Bhatt  at  Tuboscope , Indonesia.
Copyright © 1998  [Tuboscope]. All rights reserved.
Revised: January  01,1998